Robbie is very professional and always provides excellent service. I request him as my preferred technician. I would recommend him and LBA.
Very knowledgeable, very professional. He explained the system and likely reason we were having the issues that caused us to call. Checked the entire system to ensure that it was functioning according to design. Also provided clear instructions/training to his assistant while accomplishing all tasks. Please send Robby again.
Walker was here today for my furnace mtce. He was timely, professional and efficient. I'm always pleased with the service I receive
Scott is the best. Very easy to work with….always striving to find the best solution to help his customers.
They provided a great response in timely fashion to our emergency water main break.
Great service! Called late on Friday and they had a new disposal by noon on Saturday. I will be calling again!
The technician was really nice and took the time to explain any findings and suggestions.
8/19/25 - Completed a full cooling maintenance on five RTU’s. The coils were cleaned and proper operation was tested. Overall, all units were in good condition, they were all running well, and there were no issues found at this time.
8-5-25 Classroom C AC is not working, possibly bad thermostat Found RTU-1 Aaon Found the condenser fan motor contactor coil is bad, causing the control circuit breaker fuse to trip. Install new contactor condenser fan motor is working. I also replaced the run capacitor on the condenser fan motor. It was very weak. RTU#1 is working. Is it at this time? They did have a power outage the other day so I also did a visual on the other four Aaon unit are running at this time.
Went for an AC inspection today. Changed the filter. Temperature split between the supply and return duct passed. Evaporator coil is rust free. Outside system has burn marks on the contactor. Refrigerant pressures met factory specifications. Compressor amperage passed, but fan motor amperage is high. AC is up and running upon completion. Thank you for choosing LBA services!
Completed ac inspection all components tested to manufacture specifications. I recommended that they get a duct cleaning
Reviewed options. Customer chose to have spot repair done. Scheduled for Wednesday per customer's request.
****(*(*((*(*((**(*(*((*((* Rick, Left shop at 9ish, completed at 1:30. The arrival didn’t go through due to internet, didn’t discover until the job was completed. This communication wire (14/4) cannot be spliced. Only sold in 50’ or 250’. Cd jones had the 250’ for $275. I used 90’ sourced from the shop. The job went well and is completed. *)*(&)*(&&&)&()&(&(&)&&(&((**((**** Today the parts for this repair were picked up and brought onto the site. The 208v 1ph communication wire from the South evaporator head to the outside condenser was replaced and the system was function checked. The system returned to normal function after the repair was made. Thank you, Jon Tech notes: Gree, m/m multi124hp230v1co, s/n 2618GS111717. Both evap heads cooling. This is a time plus material estimate for the replacement of the 208v mini-split wire that was damaged by a squirrel. This wire supplies power to the south head unit for the mini-split system that serves the sorting room. T
I met with David and he showed me the wire that the squirrel ate through. This wire is not intended to be spliced and measurements were taken to replace the wire. The line-set enters the building through a metal wall that is very sharp. An estimate for the replacement of the damaged wire as well as adding protection to both high voltage wires that enter the building was created and emailed to David. While on-site today I located the unlabeled breaker that serves the A/C system and turned it off. In addition to this the damaged wire was removed from the outside unit and rendered safe just in case someone turns the breaker on. Thank you, Jon
Completed AC inspection for customer. All aspects tested within manufacturer specifications. No recommendations at this time. Thank you!
Completed a site survey and the site survey check sheet. It has been emailed. Thank you, Jon