Robbie is very professional and always provides excellent service. I request him as my preferred technician. I would recommend him and LBA.
Overall Experience
Quality
Price
Convenience
Very knowledgeable, very professional. He explained the system and likely reason we were having the issues that caused us to call. Checked the entire system to ensure that it was functioning according to design. Also provided clear instructions/training to his assistant while accomplishing all tasks. Please send Robby again.
Overall Experience
Quality
Price
Convenience
Walker was here today for my furnace mtce. He was timely, professional and efficient. I'm always pleased with the service I receive
Overall Experience
Quality
Price
Convenience
Scott is the best. Very easy to work with….always striving to find the best solution to help his customers.
Overall Experience
Quality
Price
Convenience
They provided a great response in timely fashion to our emergency water main break.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Great service! Called late on Friday and they had a new disposal by noon on Saturday. I will be calling again!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
The technician was really nice and took the time to explain any findings and suggestions.
Overall Experience
Quality
Price
Convenience
*)*)&)*)&)*))*)*)*)&)*)*)*)*))*)*)*)*))*)*)*)*)*)* Do not bill for fuses that are on the p.o. For this job. *)*)&)&)*)*’gmjgjgjgjgjgjtjgjf**&(&/&/$($($(($($($(&(& Today (12/2/25) a new gas valve was picked up and brought on-site. The valve was changed and the furnace was checked for electrical and mechanical functions. The furnace returned to normal function after the repair was completed. The flame sensor was removed and cleaned today as part of the heating check. The amp draws are in range, motor bearings ok, flame sensor in range and the furnace cycles properly into and out of heat mode. The estimate for today’s work is included below for reference. Thank you, Jon Tech notes: Goodman 90% nat gas furnace (twinned) Inducer motor 1.7A (rated 2.8) Blower motor amps 6.2 (rated <8) Temp rise 46 (120-74) rated: 40-70 New gas valve Control voltage 25.6acv ————————————————————————————————-, This is a time plus material estimate for the replacement of the gas v
Today (11/24/25) the furnace located above the kids’ toy area was diagnosed with a failed gas valve. A replacement valve was sourced and a repair estimate was created and sent upon David’s request. Thank you, Jon
today I did a full heating maintenance we will need to return with a service call on 2 unit heaters 1 furnace ending with serial number 1304002745 and also will need a service call for a RTU unit serial number 2105099097. All other units running as should at this time took amp draws temp splits
Went over blower and duct cleaning package with the wife. She wants to speak with her husband before making a final decision
Dispatched for furnace tune-up. The components that are tested during the tuneup are heat exchanger, flame sensor, igniter, blower wheel, inducer, temp split and combustion in the heat exchanger. During the inspection of the components the inducer was pulling to many amps on start up and was over during operation. This is indicated that the motor is need more energy to operate. The combustion test indicated high amount of carbon monoxide in the process of heating the house. The high amount is over 100ppm of carbon monoxide. This is in the exiting portion of the furnace and once the inducer shuts down the gas fall back down and enter in the furnace area of the house. The gas is turned off from the system and is red tagged due to hazardous gases. Thank you for allowing us in your house to provide the perfect home service and for being a member of the perfect family service club from your LBA Lead Service tech Calvin. If I provided a positive or five star experience. I’d appreciate
9-10-25 Spoke to David on site, the south east corner air handler above the workbench with a coffee pots and near the sprinkler room. Was making a whining sound I was able to cycle the unit in AC lower only and also furnace. I’m not getting any unusual sounds at this time. Good morning, horizontal furnace David’s gonna keep an eye on it and record it the next time it does it let us know
8/19/25 - Completed a full cooling maintenance on five RTU’s. The coils were cleaned and proper operation was tested. Overall, all units were in good condition, they were all running well, and there were no issues found at this time.
8-5-25 Classroom C AC is not working, possibly bad thermostat Found RTU-1 Aaon Found the condenser fan motor contactor coil is bad, causing the control circuit breaker fuse to trip. Install new contactor condenser fan motor is working. I also replaced the run capacitor on the condenser fan motor. It was very weak. RTU#1 is working. Is it at this time? They did have a power outage the other day so I also did a visual on the other four Aaon unit are running at this time.
Went for an AC inspection today. Changed the filter. Temperature split between the supply and return duct passed. Evaporator coil is rust free. Outside system has burn marks on the contactor. Refrigerant pressures met factory specifications. Compressor amperage passed, but fan motor amperage is high. AC is up and running upon completion. Thank you for choosing LBA services!
Completed ac inspection all components tested to manufacture specifications. I recommended that they get a duct cleaning
Reviewed options. Customer chose to have spot repair done. Scheduled for Wednesday per customer's request.